CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
FLANGE CONNECTING FACILITY AND QUANTITY | 10 UNTHREADED HOLE ALL FLANGES SINGLE CONNECTION FACILITY |
FLANGE INSIDE HEIGHT | 1.505 INCHES NOMINAL ALL FLANGES |
FLANGE CONNECTING HOLE DIAMETER | 0.263 INCHES MAXIMUM ALL FLANGES SINGLE CONNECTION FACILITY |
FLANGE DEPTH | 0.500 INCHES NOMINAL ALL FLANGES |
FLANGE INSIDE WIDTH | 3.002 INCHES NOMINAL ALL FLANGES |
FLANGE OUTSIDE HEIGHT | 3.000 INCHES NOMINAL ALL FLANGES |
FLANGE OUTSIDE WIDTH | 4.500 INCHES NOMINAL ALL FLANGES |
FLANGE QUANTITY | 2 |
FLANGE STYLE | CONTACT TYPE ALL FLANGES |
FLEXIBILITY | FLEXIBLE SINGLE TUBING SEGMENT |
FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |
MAXIMUM OPERATING PRESSURE | 35.0 POUNDS PER SQUARE INCH GAGE |
VOLTAGE STANDING WAVE RATIO | 1.08 |
WAVEGUIDE INSIDE HEIGHT | 1.334 INCHES MINIMUM AND 1.346 INCHES MAXIMUM |
WAVEGUIDE INSIDE WIDTH | 2.834 INCHES MINIMUM AND 2.846 INCHES MAXIMUM |
WAVEGUIDE OUTSIDE HEIGHT | 1.494 INCHES MINIMUM AND 1.506 INCHES MAXIMUM |
WAVEGUIDE OUTSIDE WIDTH | 2.994 INCHES MINIMUM AND 3.006 INCHES MAXIMUM |
WAVEGUIDE LENGTH | 6.000 INCHES NOMINAL |
STYLE DESIGNATOR | STRAIGHT TYPE |
SURFACE TREATMENT | ENAMEL ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES |
SURFACE TREATMENT | OXIDE FILM ALL TUBING SEGMENT AND FLANGE INSIDE SURFACES |
TUBING WALL CONSTRUCTION STYLE | CONVOLUTE SINGLE TUBING SEGMENT |