TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
51340172149ELECTRONIC TRANSFORMER CORP
G146-613-0010D0D0BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION INC.
G146-613-00188818KEARFOTT CORPORATION


Techincal Specification:
BODY HEIGHT0.900 INCHES MAXIMUM
BODY LENGTH0.900 INCHES MAXIMUM
BODY WIDTH0.770 INCHES MAXIMUM
FREQUENCY RATING10.0 KILOHERTZ NOMINAL SINGLE COMPONENT
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTIONFUNGUS RESISTANT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MAXIMUM OPERATING TEMP130.0 CELSIUS
MOUNTING METHODTERMINAL SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT15.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING CURRENT615.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE2.00 AC VOLTS NOMINAL AND 3.00 AC VOLTS NOMINAL AND 4.00 AC VOLTS NOMINAL AND 5.00 AC VOLTS NOMINAL AND 6.00 AC VOLTS NOMINAL AND 7.00 AC VOLTS NOMINAL AND 8.00 AC VOLTS NOMINAL AND 13.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE32.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE24.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING SHIELDING METHODINTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT
TERMINAL TYPE AND QUANTITY15 PIN