PILE-UP MAIN CONTACT FORM ARRANGEMENT | 1C |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 26.5 DC |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 3.0 AMPERES DC RESISTIVE LOAD |
COIL QUANTITY | 1 |
WINDING QUANTITY | 1 |
WINDING DC RESISTANCE RATING | 300.0 OHMS NOMINAL SINGLE WINDING |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 26.5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
TERMINAL TYPE AND QUANTITY | 5 PIN ALL FUNCTIONS |
DUTY TYPE | CONTINUOUS |
OVERALL LENGTH | 1.280 INCHES MAXIMUM |
OVERALL WIDTH | 0.750 INCHES MAXIMUM |
OVERALL HEIGHT | 1.370 INCHES MAXIMUM |
MOUNTING FACILITY TYPE AND QUANTITY | 4 COUPLING RING SINGLE MOUNTING FACILITY |
MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 0.375 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.375 INCHES NOMINAL SINGLE MOUNTING FACILITY |
THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY |
NOMINAL THREAD SIZE | 0.099 INCHES SINGLE MOUNTING FACILITY |
THREAD CLASS | 2B SINGLE MOUNTING FACILITY |
THREAD QUANTITY PER INCH | 48 SINGLE MOUNTING FACILITY |