DUTY TYPE | CONTINUOUS |
ARC QUENCHING METHOD | AIR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.230 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
COIL QUANTITY | 1 |
CUBIC MEASURE | 1.107 CUBIC INCHES |
ENVIRONMENTAL PROTECTION | HERMETIC |
FEATURES PROVIDED | POLARIZED |
FRAGILITY FACTOR | MODERATELY RUGGED |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 125.0 MILLIAMPERES AC AND 2.0 AMPERES DC RESISTIVE LOAD |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 30.0 DC |
OVERALL HEIGHT | 0.811 INCHES NOMINAL |
OVERALL LENGTH | 1.688 INCHES NOMINAL |
OVERALL WIDTH | 0.809 INCHES MAXIMUM |
MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED STUD SINGLE MOUNTING FACILITY |
NOMINAL THREAD SIZE | 0.112 INCHES SINGLE MOUNTING FACILITY |
NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 31.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
PURPOSE FOR WHICH DESIGNED | GENERAL |
SPECIAL FEATURES | MAX OPERATING TEMP OF 125.0 DEG C |
WINDING QUANTITY | 1 |
STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
TERMINAL TYPE AND QUANTITY | 8 WIRE HOOK ALL FUNCTIONS |
THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
THREAD DIRECTION | RIGHT-HAND SINGLE MOUNTING FACILITY |
THREAD LENGTH | 0.375 INCHES NOMINAL SINGLE MOUNTING FACILITY |
THREAD QUANTITY PER INCH | 40 SINGLE MOUNTING FACILITY |
THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY |
TIME DELAY | 0.01 SECONDS MAXIMUM FIXED RELEASE TIME |
TIME DELAY | 1.50 SECONDS NOMINAL FIXED OPERATE TIME |