AVERAGE LIFE RATING IN HOURS | 250.0 |
BODY HEIGHT | 2.000 INCHES NOMINAL |
BODY LENGTH | 2.000 INCHES NOMINAL |
BODY WIDTH | 1.120 INCHES NOMINAL |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.460 INCHES NOMINAL |
FUNCTIONAL TERMINAL TYPE AND QUANTITY | 4 TAB, SOLDER LUG OUTPUT 2ND FUNCTION |
FUNCTIONAL TERMINAL TYPE AND QUANTITY | 4 TAB, SOLDER LUG INPUT 1ST FUNCTION |
INCLOSURE TYPE | ENCASED |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
OVERALL LENGTH | 2.860 INCHES NOMINAL |
MAXIMUM VOLTAGE DROP PER FUNCTION | 0.5 VOLTS AC 2ND RADIO INTERFERENCE AND 0.5 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION |
MAXIMUM VOLTAGE DROP PER FUNCTION | 0.5 VOLTS AC 3RD RADIO INTERFERENCE AND 0.5 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION |
MAXIMUM VOLTAGE DROP PER FUNCTION | 0.5 VOLTS AC 1ST RADIO INTERFERENCE AND 0.5 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION |
MAXIMUM VOLTAGE DROP PER FUNCTION | 0.5 VOLTS AC 4TH RADIO INTERFERENCE AND 0.5 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION |
MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE |
OPERATING CURRENT RATING PER FUNCTION IN AMPS | 2.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
OPERATING CURRENT RATING PER FUNCTION IN AMPS | 2.0 4TH RADIO INTERFERENCE 4TH FUNCTION |
OPERATING CURRENT RATING PER FUNCTION IN AMPS | 2.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
OPERATING CURRENT RATING PER FUNCTION IN AMPS | 2.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
OPERATING TEMP RANGE | -55.0 TO 85.0 CELSIUS |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 4TH RADIO INTERFERENCE 4TH FUNCTION |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE 3RD FUNCTION |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE 4TH FUNCTION |
SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
UNTHREADED MOUNTING HOLE DIAMETER | 0.187 INCHES NOMINAL |
VIBRATION RESISTANCE RANGE IN HERTZ | +10.0 TO 2000.0 |