Search Criteria

NSN/NIIN No.:
Part No. :
(13-16 digit NSN/9 digit NIIN)
6685-00-016-23032910-00-016-2301
NSNDescriptionAssign Date
5950-00-016-2302TRANSFORMER,POWER01/01/1961
NSNDescriptionDetailOpen Solicitations
5950-00-016-2302TRANSFORMER,POWER0
Part NumberDescriptionCompanyQuantity
1421120TRANSFORMER DAVINCI AIRCRAFT, INC.1
For additional information Register for Free Trial
CompanyAward DateQuantityPriceContractDelivery Date
Free Trial05/16/1975Free TrialFree TrialDSA90075MSR70
Free Trial05/01/1975Free TrialFree TrialDSA90075MSR70
Free Trial09/20/1972Free TrialFree TrialDSA90073MS776
Free Trial02/10/1971Free TrialFree TrialDSA90071MDD86
For additional information Register for Free Trial
Part NumberCompanyCAGE
1421120DAIMLER CHRYSLER12204
1421120CHRYSLER CORP DAYTON PLANT 170219
2003721CHRYSLER CORP DAYTON PLANT 170219
32-81P3BETTER COIL AND TRANSFORMER CORP94617
For additional information Register for Free Trial
NameValue
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH1.938 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH2.000 INCHES MINIMUM AND 2.125 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING50.0 HERTZ NOMINAL OR 60.0 HERTZ NOMINAL SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MAXIMUM TRANSFORMER POWER RATING50.0 VOLT-AMPERE SINGLE COMPONENT
BODY LENGTH3.203 INCHES NOMINAL
BODY WIDTH2.938 INCHES MAXIMUM
BODY HEIGHT3.125 INCHES MAXIMUM
INCLOSURE TYPEFULLY INCLOSED
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
For additional information Register for Free Trial
CodeDefinition
ACQUISITION METHOD CODE.
'All Departments3ACQUIRE DIRECTLY FROM THE ACTUAL MANUFACTURER, WHETHER OR NOT THE PRIME CONTRACTOR IS THE ACTUAL MANUFACTURER.
ACQUISITION METHOD SUFFIX CODE.
'All DepartmentsCTHIS PART REQUIRES ENGINEERING SOURCE APPROVAL BY THE DESIGN CONTROL ACTIVITY IN ORDER TO MAINTAIN THE QUALITY OF THE PART. AN ALTERNATE SOURCE MUST QUALIFY IN ACCORDANCE WITH THE DESIGN CONTROL ACTIVITY’S PROCEDURES, AS APPROVED BY THE COGNIZANT GOVERNMENT ENGINEERING ACTIVITY. VALID AMCS: 1, 2, 3, 4 AND 5.
MAJOR ORGANIZATIONAL ENTITY.
NavyDNNavy
Defense Logistics Agency.DSDefense Logistics Agency.
PRICE
All DepartmentsPrice9.93
PRECIOUS METALS INDICATOR CODES.
All DepartmentsAItem does not contain Precious Metal.
CRITICALITY CODE.
All DepartmentsXThe item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
AUTOMATIC DATA PROCESSING EQUIPMENT.
All Departments
ELECTROSTATIC DISCHARGE CODE.
All Departments
HAZARDOUS MATERIALS INDICATOR CODE.
All DepartmentsPIndicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
DEMILITARIZATION CODE.
All DepartmentsANo-USML/Non-CCLI – No DEMIL or DoD TSC required. Department of Commerce may impose licensing requirements to certain destinations. (Note 9).
For additional information Register for Free Trial
TRANSFORMER, POWER IF THE APPLICABLE (OEM OR MILITARY) DRAWING, SPECIFICATION, STANDARD, OR QUALITY ASSURANCE PROVISION (QAP) SPECIFIES AN ACCEPTABLE QUALITY LEVEL (AQL), THE SAMPLING ACCEPTANCE NUMBER SHALL BE REDUCED TO ZERO (0). FOR EXAMPLE, IF THE ACCEPT REJECT CRITERIA IS ACCEPT ON (3) DEFECTS AND REJECT ON (4) DEFECTS, THE NEW ACCEPT REJECT CRITERIA IS ACCEPT ON (0) DEFECTS AND REJECT THE ENTIRE LOT ON (1) DEFECT. EVEN THOUGH THE ACCEPTANCE LEVEL IS ELIMINATED, THE SAMPLE SIZE REMAINS THE SAME. ADEQUATE DATA FOR THE EVALUATION OF ALTERNATE OFFERS IS NOT AVAILABLE AT THE PROCUREMENT AGENCY. THE OFFEROR MUST PROVIDE A COMPLETE DATA PACKAGE INCLUDING DATA FOR THE APPROVED AND ALTERNATE PART FOR EVALUATION. MERCURY OR MERCURY CONTAINING COMPOUNDS SHALL NOT BE INTENTIONALLY ADDED TO,OR COME IN DIRECT CONTACT WITH,ANY HARDWARE OR SUPPLIES FURNISHED UNDER THIS CONTRACT. EXCEPTION: FUNCTIONAL MERCURY USED IN BATTERIES, FLUORESCENT LIGHTS, REQUIRED INSTRUMENTS; SENSORS OR CONTROLS; WEAPON SYSTEMS; AND CHEMICAL ANALYSIS REAGENTS SPECIFIED BY NAVSEA. PORTABLE FLUORESCENT LAMPS AND PORTABLE INSTRUMENTS CONTAINING MERCURY SHALL BE SHOCK PROOF AND CONTAIN A SECOND BOUNDARY OF CONTAINMENT OF THE MERCURY OR MERCURY COMPOUND. (IAW NAVSEA 5100-003D). MERCURY OR MERCURY CONTAINING COMPOUNDS SHALL NOT BE INTENTIONALLY ADDED TO,OR COME IN DIRECT CONTACT WITH,ANY HARDWARE OR SUPPLIES FURNISHED UNDER THIS CONTRACT. EXCEPTION: FUNCTIONAL MERCURY USED IN BATTERIES, FLUORESCENT LIGHTS, REQUIRED INSTRUMENTS; SENSORS OR CONTROLS; WEAPON SYSTEMS; AND CHEMICAL ANALYSIS REAGENTS SPECIFIED BY NAVSEA. PORTABLE FLUORESCENT LAMPS AND PORTABLE INSTRUMENTS CONTAINING MERCURY SHALL BE SHOCK PROOF AND CONTAIN A SECOND BOUNDARY OF CONTAINMENT OF THE MERCURY OR MERCURY COMPOUND. (IAW NAVSEA 5100-003D).
Cage# 70219 and PartNumber# 1421120
Cage# 12204 and PartNumber# 1421120
Cage# 70219 and PartNumber# 2003721
Cage# 94617 and PartNumber# 32-81P3