|
|
 5915-00-009-6718 | FILTER,RADIO FREQUENCY INTERFERE | 08/04/1972 |
|
 5915-00-009-6718 | FILTER,RADIO FREQUENCY INTERFERE | | 0 |
|
|
For additional information Register for Free Trial
|
 RF02500-3 | EMS DEVELOPMENT CORPORATION | 13619 | RF2500-3 | EMS DEVELOPMENT CORPORATION | 13619 | 2994446 | NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY | 10001 | 81-308-601 | SPECTRUM CONTROL INC | 33095 | 2994446 | LOCKHEED CORP LOCKHEED ELECTRONICS CO INC | 87557 | For additional information Register for Free Trial
|
 OVERALL LENGTH | 1.789 INCHES NOMINAL | BODY LENGTH | 0.975 INCHES NOMINAL | BODY OUTSIDE DIAMETER | 0.406 INCHES NOMINAL | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS BLANK | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNF | INCLOSURE TYPE | ENCASED | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING 3RD FUNCTION | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 TAB, SOLDER LUG INPUT 1ST FUNCTION | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 TAB, SOLDER LUG OUTPUT 2ND FUNCTION | MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 125.0 VOLTS AT SEA LEVEL | For additional information Register for Free Trial
|
 ACQUISITION METHOD CODE. | 'All Departments | 1 | SUITABLE FOR COMPETITIVE ACQUISITION. |
| ACQUISITION METHOD SUFFIX CODE. | 'All Departments | C | THIS PART REQUIRES ENGINEERING SOURCE APPROVAL BY THE DESIGN CONTROL ACTIVITY IN ORDER TO MAINTAIN THE QUALITY OF THE PART. AN ALTERNATE SOURCE MUST QUALIFY IN ACCORDANCE WITH THE DESIGN CONTROL ACTIVITY’S PROCEDURES, AS APPROVED BY THE COGNIZANT GOVERNMENT ENGINEERING ACTIVITY. VALID AMCS: 1, 2, 3, 4 AND 5. |
| MAJOR ORGANIZATIONAL ENTITY. | Navy | DN | Navy | Defense Logistics Agency. | DS | Defense Logistics Agency. |
| PRICE | All Departments | Price | 57.00 |
| PRECIOUS METALS INDICATOR CODES. | All Departments | U | Precious Metal type is unknown. |
| CRITICALITY CODE. | All Departments | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| AUTOMATIC DATA PROCESSING EQUIPMENT. | | ELECTROSTATIC DISCHARGE CODE. | | HAZARDOUS MATERIALS INDICATOR CODE. | All Departments | P | Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. |
| DEMILITARIZATION CODE. | All Departments | A | No-USML/Non-CCLI – No DEMIL or DoD TSC required. Department of Commerce may impose licensing requirements to certain destinations. (Note 9). |
| For additional information Register for Free Trial |
|  | | FILTER,RADIO FREQUENCY IF THE APPLICABLE (OEM OR MILITARY) DRAWING, SPECIFICATION, STANDARD, OR QUALITY ASSURANCE PROVISION (QAP) SPECIFIES AN ACCEPTABLE QUALITY LEVEL (AQL), THE SAMPLING ACCEPTANCE NUMBER SHALL BE REDUCED TO ZERO (0). FOR EXAMPLE, IF THE ACCEPT REJECT CRITERIA IS ACCEPT ON (3) DEFECTS AND REJECT ON (4) DEFECTS, THE NEW ACCEPT REJECT CRITERIA IS ACCEPT ON (0) DEFECTS AND REJECT THE ENTIRE LOT ON (1) DEFECT. EVEN THOUGH THE ACCEPTANCE LEVEL IS ELIMINATED, THE SAMPLE SIZE REMAINS THE SAME. THE USE OF ANY CLASS I OZONE-DEPLETING SUBSTANCE (ODS) IN THE DESIGN, MANUFACTURING, TESTING, CLEANING, OR ANY OTHER PROCESS FOR THIS ITEM UNDER ANY MILITARY OR FEDERAL SPECIFICATION, STANDARD OR DRAWING REFERENCED IN THIS ITEM DESCRIPTION IS "PROHIBITED" UNLESS THE SEPARATE WRITTEN APPROVAL OF THE CONTRACTING OFFICER IS OBTAINED. THIS PROHIBITION SUPERSEDES ALL SPECIFICATION REQUIREMENTS BUT DOES NOT ALLEVIATE ANY PRODUCT PERFORMANCE REQUIREMENTS. THIS DOES NOT APPLY TO COMMERCIAL ITEMS, AS DEFINED IN "FAR 11.001" OR TO PART-NUMBERED- ONLY ITEMS. ADEQUATE DATA FOR THE EVALUATION OF ALTERNATE OFFERS IS NOT AVAILABLE AT THE PROCUREMENT AGENCY. THE OFFEROR MUST PROVIDE A COMPLETE DATA PACKAGE INCLUDING DATA FOR THE APPROVED AND ALTERNATE PART FOR EVALUATION. |
|
|
|
|
|
|
|
|
|