Search Criteria

NSN/NIIN No.:
Part No. :
(13-16 digit NSN/9 digit NIIN)
5340-01-182-67325340-01-182-6490
NSNDescriptionAssign Date
5340-01-182-6730COVER,ACCESS06/27/1984
NSNDescriptionDetailOpen Solicitations
5340-01-182-6730COVER,ACCESS0
Part NumberDescriptionCompanyQuantity
16B1736-7COVER CHRISBARRY AIRCRAFT CORP1
For additional information Register for Free Trial
CompanyAward DateQuantityPriceContractDelivery Date
Free Trial09/10/2015Free TrialFree TrialSPE4A715MA920 05/09/2016
Free Trial07/22/2014Free TrialFree TrialSPE4A714MB027 11/16/2015
For additional information Register for Free Trial
Part NumberCompanyCAGE
16B1736-7LOCKHEED MARTIN CORPORATION81755
For additional information Register for Free Trial
NameValue
END ITEM IDENTIFICATIONF-16C/D USAF AIRCRAFT
SPECIAL FEATURESPLIES 1-5 FMS-3015,PLIES 1-6 FMS-1025,CLASS 4;PROCESS,BOND AND QC PER FPS-3026;LOCATION-OVER ELECTRICAL HARNESS-EMI REDUCTION,RADOME,LH;WL 92.59,BL 16.53;EFF ON-0001 9999
MATERIALGLASS FIBER
MATERIAL DOCUMENT AND CLASSIFICATIONFMS-3015,STYLE 181 FED STD SINGLE MATERIAL RESPONSE
For additional information Register for Free Trial
CodeDefinition
ACQUISITION METHOD CODE.
'All Departments1SUITABLE FOR COMPETITIVE ACQUISITION.
ACQUISITION METHOD SUFFIX CODE.
'All DepartmentsGTHE GOVERNMENT HAS UNLIMITED RIGHTS TO THE TECHNICAL DATA AND THE DATA PACKAGE IS COMPLETE. VALID AMCS: 1 AND 2.
MAJOR ORGANIZATIONAL ENTITY.
Air ForceDFAir Force
Defense Logistics Agency.DSDefense Logistics Agency.
PRICE
All DepartmentsPrice11870.42
PRECIOUS METALS INDICATOR CODES.
All DepartmentsAItem does not contain Precious Metal.
CRITICALITY CODE.
All DepartmentsXThe item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
AUTOMATIC DATA PROCESSING EQUIPMENT.
All Departments0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9).
ELECTROSTATIC DISCHARGE CODE.
All Departments
HAZARDOUS MATERIALS INDICATOR CODE.
All DepartmentsPIndicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
DEMILITARIZATION CODE.
All DepartmentsQCommerce Control List Items (CCLI) – Mutilation to the point of scrap required outside the United States. In the United States, mutilation requirement determined by the DEMIL Integrity Code. DoD Trade Security Controls (TSC) required in the United States. (Note 8).
For additional information Register for Free Trial
COVER,ACCESS P/N 16B1736-7 Government First Article Preproduction approval required. Testing will be in accordance with applicable drawings, specifications and/or Engineering instructions. The first article offered shall be manufactured at the facilities in which production quantities are procured and produced under this contract. When submitting the first article(s) for government testing, a copy of the contract and all applicable drawings, specifications, engineering instructions, certifications, and inspection sheets shall be provided. Upon receipt and evaluation of the test report from the responsible government testing location, the contracting officer will provide final notification to the manufacturer. Any questions or concerns regarding the first article test requirements must be submitted through the contracting officer. Additional Wide Area Workflow (WAWF) instructions for government first article test CLIN: The contractor shall code the receiving report for government first article test CLIN in WAWF as Follows: Inspection at origin (Source)- Enter the DCMA office DODAAC listed on page 1 of the contract. Acceptance by other-Enter the issue by office DODAAC listed on page 1 of the contract. Ship to code-Enter the DODAAC of the test facility listed for the government first article test CLIN in the contract (See FAR Clause 52.209-4). FIRST ARTICLE TEST MARKING INSTRUCTIONS: FAT sample(s) packaging shall be clearly marked "FIRST ARTICLE TEST EXHIBIT(S) DO NOT POST TO STOCK!!!" in largest font possible with contrasting color to the packaging. Marking shall be located adjacent to the Package Shipping Label side and on at least one additional side of the package. EXCEPTIONS TO DRAWING 16B1736-7 AS NOTED: SPECIAL INSTRUCTIONS FOR NSN 1560-01-182-6730 PART NUMBER: 16B1736-7 ENGINEERING DATA REQUIREMENTS DTD AUG 27, 2004 1.0 THE FOLLOWING SPECIFICATIONS/STANDARDS, ETC., WILL BE USED IN LIEU OF THE DATA INDICATED. THE SUPERSEDED DATA WILL NOT BE FURNISHED UNLESS SO INDICATED. 1.1 THE SOURCES/MATERIALS IF LISTED ON THE SPECIFICATION, STANDARDS AND DRAWINGS ARE THE ONLY SOURCES/MATERIALS FOR THOSE ITEMS. ANY SUBSTITUTIONS SHALL HAVE PRIOR APPROVAL BY THE COGNIZANT OO-ALC ENGINEERING ACTIVITY. 1.2 PART MARKING AS PER MIL-STD-130 IN LIEU OF FPS-3008. 1.2 16PR006 IS NOT FURNISHED, USE IGES LOFT DATA 16B1736-7 FOR MANUFACTURING. ...END OF SPECIAL INSTRUCTIONS... CRITICAL APPLICATION ITEM: MARK IAW MIL-STD-130N, DATED 17 DEC 2007. CONFIGURATION CONTROL APPLIES SEE CLAUSE 52.246-9G36 (SECTION I). FIRST ARTICLE REQUIREMENTS: ADDITIONAL FAT INFORMATION: ATTN: CONTRACTOR AND SERVICE ACTIVITY TEST MONITIOR........................................ DISAPPROVED FIRST ARTICLE(S) SHALL BE RETURNED TO THE CONTRACTOR AT THE CONTRACTOR'S EXPENSE. APPROVED AND CONDITIONALLY APPROVED FIRST ARTICLE(S) SHALL BE RETAINED AT THE SERVICE TEST ACTIVITY UNTIL DISPOSITION INSTRUCTIONS ARE RECEIVED FROM THE PCO. IF DISPOSITION INSTRUCTIONS ARE NOT RECEIVED WITHIN 30 DAYS AFTER PROVIDING THE FIRST ARTICLE TEST REPORT TO DSCR, REQUEST THAT THE DSCR QA SPECIALIST BE NOTIFIED....................... TECHNICAL DATA AVAILABILITY: SAMPLING: 1. SAMPLING FOR INSPECTION AND TESTING SHALL BE IAW ANSI/ASQ Z1.4-2008, DATED JAN 1, 2008. ANY ALTERNATE PLAN MUST BE APPROVED BY THE PCO. A SAMPLING PLAN THAT ACCEPTS ON ZERO DEFECTS IS REQUIRED 2. ANY DEFECTIVE ITEM DISCOVERED DURING INSPECTION MAY BE CAUSE FOR REJECTION OF THE ENTIRE CONTRACT QUANTITY. THIS ITEM HAS TECHNICAL DATA SOME OR ALL OF WHICH IS SUBJECT TO EXPORT-CONTROL REGULATIONS. DISTRIBUTION OF THE TECHNICAL DATA AND ELIGIBILITY FOR AWARD ARE LIMITED TO THOSE SUPPLIERS QUALIFIED THROUGH JCP CERTIFICATION, OR TO THOSE LICENSED BY EITHER THE DEPARTMENTS OF STATE OR COMMERCE; OR TO FOREIGN SUPPLIERS PURSUANT TO INTERNATIONAL AGREEMENTS. TO APPLY FOR JCP CERTIFICATION, COMPLETE DD FORM 2345, "MILITARY CRITICAL TECHNICAL DATA AGREEMENT," FORM IS AVAILABLE AT THE WORLD WIDE WEB ADDRESS HTTP://WWW.DLIS.DLA.MIL/JCP OR BY WRITING TO: DLA LOGISTICS INFORMATION SERVICE FEDERAL CENTER 74 WASHINGTON AVE., NORTH BATILE CREEK, MI 49017-3084 TO MANUFACTURE THIS ITEM, NON-JCP CERTIFIED SUPPLIERS MUST SUBMIT A CURRENT MANUFACTURING LICENSE AGREEMENT, TECHNICAL ASSISTANCE AGREEMENT, DISTRIBUTION AGREEMENT OR OFF-SHORE PROCUREMENT AGREEMENT APPROVED BY THE DIRECTORATE OF DEFENSE TRADE CONTROLS WITH THE OFFER, UNLESS AN EXEMPTION UNDER THE PROVISIONS OF ITAR SECTION, 125.4 "EXEMPTIONS OF GENERAL APPLICABILITY," AND/OR EAR PART 740 ARE APPLICABLE. NON-JCP CERTIFIED SUPPLIERS SEEKING EXPORT CONTROLLED TECHNICAL DATA ARE REQUIRED TO PROVIDE THE CONTRACTING OFFICER WITH AN APPLICABLE AGREEMENT OR IDENTIFY WHICH ITAR/EAR EXEMPTION APPLIES TO RECEIVE A COPY OF THE EXPORT CONTROLLED TECHNICAL DATA. NOTE: JCP CERTIFIED CONTRACTORS WHO RECEIVE TECHNICAL DATA PURSUANT TO THEIR DD FORM 2345 CERTIFICATION MAY NOT FURTHER DISSEMINATE SUCH DATA UNLESS FURTHER DISSEMINATION OF THE TECHNICAL DATA IS EXPRESSLY PERMITTED BY DODD 5230.25."
Doc. NumberDoc. TypeDoc. Def.Doc. CodeDoc. DateAmdt. DateCage
FQML-1026-32DWGBASICML11/27/200703/20/2014 81755
16PR070DWGBASICCN10/24/199402/18/2014 81755
16PR070-APPENDIX-BDWGBASICAP05/21/200311/26/2013 81755
FQML-1025DWGBASICML06/28/201111/07/2013 81755
FPS-3001DWGBASICCN02/03/200308/31/2013 81755
16Z001ISS204DWGBASICPL12/21/201108/29/2013 81755
16Z001ISS204DWGBASICAL12/21/201102/22/2012 81755
FPS-3001DWGBASICSS07/21/201011/01/2010 81755
FMS-1025DWGBASICAM01/27/200601/28/2010 81755
16PR070-APPENDIX-ADWGBASICAP05/21/200310/27/2009 81755